Question List
Subject:
BR B-602 Structural Steel
Type:
Plan
Question
Date:
12/16/2025 2:21:50 PM
Is Bridge B-602 Structural Steel to be painted? If so what color?
Answer
Date:
12/17/2025 7:34:08 AM
Bridge B602 Structural Steel is not to be painted.
Subject:
4260 Time Lapse Monitoring System
Type:
Plan
Question
Date:
12/14/2025 10:20:15 PM
Please clarify where this item is located in the plan pages and the spec "ATTD" has not been provided.
Answer
Date:
12/15/2025 12:36:09 PM
The specifications for the Time Lapse Monitoring System are found in the Special Provision for Time-Lapse Camera and Video Monitoring System, beginning on page 297 of the proposal. The specific placement of the devices are to be established in accordance with the special provision.
Subject:
1210 - Porous Backfill
Type:
Bid Sheet
Question
Date:
12/12/2025 3:15:34 PM
The bid item list shows 202 CY of Porous backfill in item 1210. B603 lists 99 CY of Porous Backfill on the quantity summary. None of the other structures show porous backfill as an item. What is the remaining quantity intended for?
Answer
Date:
12/15/2025 12:35:27 PM
Porous Backfill is also used at the RW-3s on roadway plan sheets 23 and 24, quantified on roadway summary sheet 2J(2).
Subject:
Sounds Barrier Wall Coating and Stain
Type:
Specifications
Question
Date:
12/12/2025 12:08:59 PM
The SP for Sound Barrier Walls and Architectural Finishes states that all panels shall be colored on both sides, and the color shall be No. 36495. Architectural Treatment section 4 describes a color stain coating. Can the Department please confirm if the architectural treatment shall be stained a different color than those areas of the panel with a plain concrete finish, or is the panel, including the architectural finish, all one color (No. 36495). If the architectural finish to be stained, please provide details on the required colors.
Answer
Date:
12/15/2025 12:34:47 PM
No color coating will be applied to the posts or the 8-inch "coping area" at the top of the panels, they are to remain the natural color. The wall panels, below the coping area, shall receive color coating (including doors).
Subject:
Bid Date
Type:
Other
Question
Date:
12/12/2025 10:03:58 AM
Given the number of RFI questions still to be answered, some that are relatively technical in nature, is there potential for the bid date to be extended?
Answer
Date:
12/15/2025 12:34:18 PM
An extension will not be issued.
Subject:
FRP
Type:
Specifications
Question
Date:
12/12/2025 10:02:36 AM
Detail F-1 / Sheet 18 of 84 (Plan No. 305-70) – Backwall Wrapping Please confirm whether the FRP shown in Detail F-1 is intended to fully wrap the backwall or be applied as a U-wrap from the top of the backwall only.
Answer
Date:
12/15/2025 12:33:33 PM
Detail F-1 references Plan View H-H, which indicates the intent to fully wrap the backwall after saw cutting.
Subject:
Abutment Schematics
Type:
Specifications
Question
Date:
12/12/2025 10:01:58 AM
Please verify the abutment schematics for FRP installation shown in Bridge Plan 305-66. The drawings do not clearly indicate which abutment sections correspond to the existing bridge, and which correspond to the new bridge.
Answer
Date:
12/15/2025 12:33:04 PM
Fiber wrap is only applied to surfaces exposed by saw cutting on the existing bridge. Details on this sheet only apply to the existing bridge.
Subject:
Coatings
Type:
Specifications
Question
Date:
12/12/2025 10:01:28 AM
Please confirm whether a protective coating is required over the installed FRP. If a coating is required, we recommend an acrylic coating compatible with the FRP system that provides waterproofing and UV protection, which is typically recommended for bridge applications.
Answer
Date:
12/15/2025 4:12:19 PM
Please bid in accordance with the current contract documents.
Subject:
Quantities
Type:
Specifications
Question
Date:
12/12/2025 10:00:54 AM
The FRP quantities shown on the “Estimated Quantities” sheet appear to be lower than the quantities implied by the FRP details and wrapping requirements shown in the contract drawings. Please clarify: • Should the bid be based on the estimated quantities provided, or on the FRP quantities required to implement the strengthening details fully? • If the latter, how should this be qualified in the bid (e.g., lump sum based on details, unit-price adjustment, or quantity reconciliation during construction)?
Answer
Date:
12/15/2025 12:30:29 PM
The FRP quantities have been verified. Any deviation from the estimated quantities will be handled in accordance with Section 104.02 of the Specifications.
Subject:
Settlement Plate
Type:
Plan
Question
Date:
12/11/2025 5:11:37 PM
Where is the Settlement Plate to be utilized?
Answer
Date:
12/13/2025 11:01:37 AM
The settlement plate is shown on Sheet 8D, at Station 206+50.40 RT.