Advertisements   Division Home   Bid Results   Bid Tabs   Ad Report   VDOT Forms
Project Info
Order Number UPC State Project Number Last Date to Post Questions
L01 115480 0089-038-791,C501 3/22/2024
Search Questions
Search
Question Type  
    The last date to post questions has passed. Any questions posed 72 hours before the letting date may not be answered. Export Q&A    
Question List
Subject: 24" Bored & Jacked Pipe Type: Plan
Question Date: 3/13/2024 9:28:23 AM
PerSheet 9(4) the 24" pipe from 4-2 to 4-13 is shown to be a bored & jacked RCP. 1. can this B&J pipe be Welded Steel Pipe in-lieu of concrete? 2. Per sheet 8 the pipe from 4-2 to 4-13 is shown to receive a cradle as well. How can the pipe be both bored and jacked and have a CIP cradle?  
Answer   Date: 3/13/2024 1:49:04 PM
The pipe needs to be concrete, with the intent of providing a concrete cradle under the upstream portion that can be installed by open cut, then continuing without for the jack & bore portion.  
 

Displaying questions 1 - 1 (of 1)
Page: 1 First Previous Next Last