Subject: chain tension assemblies Type: Plan
Question Date: 5/4/2016 3:31:55 PM
Please provide some clarification regarding the chain tensioning assemblies shown on 11 of 14. What is the purpose of the tensioners? Is there a known domestic source for this device or is it expected to be custom fabricated?  
Answer   Date: 5/18/2016 9:58:33 AM
The chain tensioners are included to provide for fine adjustment of the beam location and levelness. These tensioners are used in the marine industry and a galvanized version is currently installed on the ferry bumpers at this site. These chain tensioners are available domestically or they may be fabricated of components meeting the working load requirements.  
 
Subject: Jobsite Access Type: Other
Question Date: 5/4/2016 3:19:22 PM
Recently, a project was bid to replace wood pile dolphins with monopiles at the jobsite. According to the schedule in the specifications, these two projects will occur simultaneously. Both contractors will need to occupy the same area in the slips with their floating equipment. Potentially, one contractor could impact the other contractors schedule. How will this be coordinared?  
Answer   Date: 5/16/2016 3:28:18 PM
The wining Contractors shall follow Section 105.09 of the Specification; in addition, the Ferry Operation Staff and Construction Division will assist in this coordination and are aware of the two projects occurring simultaneously.  
 
Subject: AISC Certified Shop Type: Specifications
Question Date: 5/4/2016 3:05:56 PM
According to the plans, steel fabrications shall be fabricated in a ASIC Certified shop. Will the shop need SBR or CBR certification? Or will BU certification be sufficient?  
Answer   Date: 5/12/2016 4:05:32 PM
Per VDOT Specifications 407.04, Structural steel shall be fabricated in a shop certified by AISC, Category SBR or CBR, with endorsements for fracture critical and/or painting as appropriate.  
 