Question List
Subject: Trench Backfill Type: Specifications
Question Date: 4/26/2021 4:59:31 PM
If the regular backfill is determined as unsuitable for backfilling trenches, will the disposal and fill replacement be paid as a change order?  
Answer   Date:
 
 
Subject: Deadline of April 28th Type: Other
Question Date: 4/23/2021 3:30:47 PM
Due to the quantity and complexity of the questions, could you please consider changing the deadline to 5/05/2021 to allow extra time to make necessary bid adjustments.  
Answer   Date:
 
 
Subject: RW3 Type: Specifications
Question Date: 4/23/2021 1:17:49 PM
Is there a detail for RW3? Drawings show standard RW3 which is a gravity wall (between stations 108+25' to 110+75') but we cant find any details for that gravity wall.  
Answer   Date: 4/23/2021 3:28:42 PM
The profile for the VDOT Standard RW-3 is on Sheet 4A(1) and the detail is available in Section 400 of the VDOT Road and Bridge Standards.  
 
Subject: Page 7, Line Number 0740 Type: Other
Question Date: 4/23/2021 12:36:09 PM
Please explain/define the 86,400 (day)  
Answer   Date: 4/23/2021 3:28:31 PM
Refer to the Maintenance of Traffic Summary on Sheet 2J for the summary of Group 2 Channelizing Devices by phases and Section 512.04 of the VDOT Road and Bridge Specifications.  
 
Subject: RW3 Type: Specifications
Question Date: 4/23/2021 11:05:06 AM
Please provide a rebar schedule.  
Answer   Date: 4/23/2021 11:20:03 AM
Refer to sheets 12(3) and 12(6).  
 
Subject: Dumpsite Type: Specifications
Question Date: 4/22/2021 3:07:54 PM
Does VDOT have a designated area to dump the excess material at, or is the contractor responsible for providing and paying for a dumpsite?  
Answer   Date: 4/23/2021 11:19:47 AM
VDOT does not have a designated disposal site. It is the responsibility of the contractor to secure a support facility to dispose of materials in accordance with IIM-LD-242.  
 
Subject: Type: Proposal
Question Date: 4/21/2021 2:19:33 PM
Please clarify the Bus Shelter dimensions. It measures approximately 72 square feet in the plans, but the Special Provisions call out 72 square yards.  
Answer   Date: 4/23/2021 11:31:25 AM
The bus shelter will be a minimum of 72 square feet. The special provision will be corrected after award.  
 
Subject: 60" Culvert Extension Type: Plan
Question Date: 4/21/2021 1:33:50 PM
Will the contractor be responsible for cleaning and debris removal for the existing 60" culverts?  
Answer   Date: 4/23/2021 11:34:48 AM
No. The contractor is only required to extend the pipes in accordance with the plans.  
 
Question Date: 4/7/2021 9:41:06 AM
Is a detail available for the connection of the new 60" pipes to the existing pipes? One crossing has a mitered end and the other has a headwall. The plans do not indicate if the existing headwall is to be removed, or portions of the mitered ends removed.  
Answer   Date: 4/14/2021 4:42:47 PM
The drainage descriptions note that polymer coated steel coupling bands are required for each of the CMP pipe extensions. For the coupler to fit properly, the mitered cut section will need to be cut flush/vertical and the existing headwall removed. The cost of removal shall be included in the price bid for regular excavation in accordance with General Note G-4. The 35’ length on the culvert extensions at Str. 6-5 where the existing headwall is located accounts for the headwall removal. The 40’ length of the culvert extensions at Str. 5-16 accounts for 8’ of the mitered cut section removal. No additional detail is available.  
 
Subject: C-111 Submittal Type: Other
Question Date: 4/21/2021 12:32:30 PM
Will the C-111 forms need to be prepared for the base bid and both alternates? Or will the determination of over/under budget for the alternates be announced when the bids are read, and only the applicable scenario prepared?  
Answer   Date: 4/23/2021 5:35:59 PM
The C-111 should be prepared for combination of the Base Bid, Additive 1, and Additive 2. Should the Department's available funding require reduction of scope by not awarding Additive 1 or 2 a revised C-111 will be requested.  
 
Subject: Signage Type: Bid Sheet
Question Date: 4/20/2021 2:50:58 PM
The schedule of signs shows 22 EA 2 1/2", 12 Gauge posts but there is no line item for these, only 2 1/2" 10 gauge posts. Will they all be paid for under this line item?  
Answer   Date: 4/23/2021 11:39:24 AM
All sign posts and foundations will be in accordance with the sign schedule on sheet 11(7). This will result in the addition of 228 LF of Sign Post STP-1, 2 ½”, 12 Gauge (Item Code 50436) and 3 EA Concrete Sign Foundation STP-1, TYPE B (Item Code 50486). There will be a corresponding reduction in the quantity of Sign Post STP-1, 2 ½” 10 Gauge (Item Code 50434) to 36 LF and Concrete Sign Foundation STP-1, Type A (Item Code 50485) to 19 EA. The changes will not be reflected in the plans or contract until after the bid letting.  
 