Advertisements   Division Home   Bid Results   Bid Tabs   Ad Report   VDOT Forms
Project Info
Order Number UPC State Project Number Last Date to Post Questions
C53 109471 0003-036-610, C501 4/17/2020
Search Questions
Search
Question Type  
    The last date to post questions has passed. Any questions posed 72 hours before the letting date may not be answered. Export Q&A    
Question List
Subject: Utility Relocation Type: Bid Sheet
Question Date: 4/15/2020 3:12:18 PM
For bid item 0450 - Utility Relocation, what work is included in this bid item?  
Answer   Date:
 
 
Subject: Outstanding Questions Type: Other
Question Date: 4/1/2020 11:45:05 AM
When is the department going to answer the questions? We need to give our suppliers enough time to provide quotes.  
Answer   Date: 4/2/2020 7:30:24 PM
Answers have been posted.  
 
Subject: Test Bore Type: Bid Sheet
Question Date: 3/26/2020 4:47:38 PM
There are a quantity of 6 test bores for this project and only 2 signal poles. Can you clarify what the other 4 test bores are for?  
Answer   Date: 4/2/2020 7:25:13 PM
Contract quantity will be revised to 2 EA.  
 
Subject: Removing Existing Signal Equipment Type: Plan
Question Date: 3/26/2020 4:44:37 PM
Sheet 7(02) note 1 references removing all aspects of the existing traffic signal. Should the removal line items be deleted? Item 0310, 0840, and 0850 are in question.  
Answer   Date: 4/2/2020 7:26:36 PM
Line Items will be removed from the Proposal by revision.  
 
Subject: Emergency Preemption Type: Bid Sheet
Question Date: 3/26/2020 4:34:22 PM
The bid sheet has a line item (0690) for a 4-way preemption and the plans show a 3-way. Please clarify.  
Answer   Date: 4/2/2020 7:27:12 PM
Item Description will be revised to 3-Way system.  
 
Subject: Traffic Signal Heads Type: Bid Sheet
Question Date: 3/26/2020 4:32:34 PM
There are two line items for the signal heads. Item 0570 with a quantity of 50 and item 0910 with a quantity of 50. Please clarify why both items are needed.  
Answer   Date: 4/2/2020 7:28:17 PM
Item 0570 will be removed from the proposal by revision.  
 
Subject: Traffic Signal Cabinet Type: Bid Sheet
Question Date: 3/26/2020 4:28:43 PM
Please add line item for controller cabinet.  
Answer   Date: 4/2/2020 7:29:08 PM
Item will be added to the proposal.  
 
Subject: Discrepancies between the line items and drawings Type: Bid Sheet
Question Date: 3/26/2020 4:27:35 PM
Item 0460 Sign Panel has 110 sf on the bid sheet and the drawings total 297.42 sf between the signs and traffic signal. Item 0530 Conc Sign Found STP-1 Ty F has 9 on the bid sheet and the drawings do not show any. Item 0540 Rem Ty I Signs has 19 on the bid sheet and the drawings show 12. Item 0630 Conc Foundation CF-4 has 1 listed on the bid sheet and the drawings do not show any. Item 0660 Mast Arm 60' has 1 on the bid sheet and the drawings do not show any. Item 0720 Detector Rack Mounted Inductive Loop Amplifier has 5 on the bid sheet and the drawings do not show any. Item 0750 Cond Cable EVP Detector (Cable GPS) has 90 on the bid sheet and the drawings do not show any. Item 0790 Hanger Assy SMB-3 One Way has 4 on the bid sheet and the drawings do not have any. Items 0870, 0880, 0890 for the UPS show 1 each on the bid sheet and the drawings do not show any. Item 1000 8 Cond Cable has 1,000 on the bid sheet and the drawings do not show any. Item 1030 Junction Box JB-S2 has 5 on the bid sheet and the drawings do not show any. Item 1140 Comm Equip Wireless Cellular Router has 1 on the bid sheet and the drawings do not show any.  
Answer   Date: 4/2/2020 7:30:07 PM
Discrepancies will be corrected by revision.  
 

Displaying questions 1 - 8 (of 8)
Page: 1 First Previous Next Last