Advertisements   Division Home   Bid Results   Bid Tabs   Ad Report   VDOT Forms
Project Info
Order Number State Project Number Last Date to Post Questions
D10 U000-158-281,B604 7/17/2020
Question
Question Date: 7/15/2020
There are no provisions allowed for draining the select back fill behind the rigid frame or wing walls. Will the department require geo-composite wall drain and outlet pipe? If so how will this be paid?
Answer History
Previous Answers PostDate
Geo-composite walls drains and weep holes in accordance with the “For conventional shelf/cantilever abutments” detail in Vol. V, Part 2, Sheet 5 of 8, File No. 17.12-5, shall be included in the cost of the Precast Concrete Rigid Frame. 7/20/2020
Geo-composite walls drains, if required by the precast designer, shall be included in the cost of the Precast Concrete Rigid Frame. 7/20/2020